Item | Detecting Condition | Possible cause |
DTC Strategy | | Battery Voltage Monitoring |
| | Open or short of power supply circuit |
| Blown fuse |
| Faulty HECU |
|
Case1 (Motor Relay Open orMotor Short to GND) | Enable Conditions | | If the motor relay is switched ON and motor voltage < (IGN voltage – 4V±0.5V) continued for 49msec, the failure is detected. |
|
Case2 (Motor Lock) | Enable Conditions | | After motor relay is switched OFF, VMR is measured. If the time which VMR > 1±0.1V is less than evaluation time, recheck is performed again for a maximum of three times. When VMR is not normal even on the third recheck, the controller recognizes it as failure. |
|
Case3 (Motor Open, Motor Short to BATT) | Enable Conditions | | After 1.8sec from the time that motor relay is switched OFF, VMR > 4±0.5V continued for 1.8sec, the failure is detected. |
|
Case4 (Motor Fuse Open) | Enable Conditions | | If the motor relay is switched OFF and VMRP (Motor power supply voltage) < 4±0.5V continued for 1sec, the failure is detected. |
|
Fail Safe | | ABS/ESP functions are inhibited, EBD function is allowed and the ABS/ESP warning lamps are activated. |
|